Saturday, November 11, 2017

Renewable Energy Better Than All Else - Unsubsidized

Subtitle: Lazard Study Shows Wind is Lowest Cost for Generation

One of the ongoing debates is what is the best technology, or mix of technologies, to provide safe, reliable, affordable, and low-polluting electric power for public consumption.  SLB has quite a few articles on this to date. see link   SLB holds the view that renewable energy systems, especially wind turbines and solar power systems, were not economically viable for many years, but that has changed for the better in the past few years due to ongoing federal and state subsidies.    In addition, SLB holds the view that commercial nuclear power plants are far too expensive to build and operate, plus those that presently are operating should be shut down because they are 1) unsafe, and 2) not economic.  Also, SLB holds the view that coal-fired power plants in the US should be forced to curb their emissions to meet the Clean Air Act requirements, and compete in the power market if they are able.   The stark reality for coal plants is they cannot compete after making the
Figure 1.  Lazard LCOE v 11.0 - page 2showing Wind as lowest, Nuclear as 4X Wind(Wind, Nuclear, and Coal circled in blue)
expenditures for pollution abatement equipment.   SLB also holds the view that natural gas-fired power plants that use the combined-cycle technology, CCGT, should be installed to the maximum extent possible due to the low capital cost, low operating cost, effective load-following ability, and almost zero pollution.    These views are based on the best data available, both recent past and current.   Despite being data and evidence-based, these views provoke howls of outrage from many commenters on other blogs.  


In the midst of all this, the Secretary of Energy, Rick Perry, has proposed that the US provide yet another subsidy for nuclear plants and coal plants.   The basis for that new subsidy is the supposed benefit to electric power grids from steady, almost continuous baseload power that the nuclear plants and (some) coal plants provide.   That topic will be the basis for another post, however.   It should be noted that a grid does not need nuclear power for baseload, indeed, several states and many grids have no nuclear plants operating.   Also, coal-fired power plants are not required for baseload for a stable grid.   

Today's article is to highlight and discuss a recent study by Lazard, (worldwide financial advisory and asset management services firm), titled "Lazard's Levelized Cost of Energy Analysis - Version 11.0" see link 

LCOE Calculation

Lazard has (on p. 17) a brief description of how it calculates the LCOE, Levelized Cost of Energy:  for each technology, using installed capital costs, operating costs, financing via debt and equity, Lazard solves for the $/MWh that provides the required Internal Rate of Return (IRR) for the equity investors.    This is a sound methodology, one that SLB has also used in such calculations.   Note that the Lazard LCOE is a leveraged financing calculation, for example in Wind power, 60 percent debt is allowed at 8 percent per year (presumably long-term bonds), and 40 percent equity is at 12 percent (presumably Preferred Stock with a 12 percent annual return).   This is a slightly more complex calculation than others use, where the $/MWh LCOE is determined with a simple 10 percent return on installed costs, plus all operating costs.   (But, note that the Lazard cost of capital for Wind is then 9.6 percent (0.6 x 8 + 0.4 x 12 = 9.6), almost the same compared to the simpler case of 10 percent). 

The primary results, as shown in Figure 1 above, show that Wind LCOE, unsubsidized, is $30/MWh, (3 cents per kWh).   The vertical red line shows that literally nothing, renewable or conventional technologies, has a lower LCOE.  

A note on the unsubsidized aspect of the Lazard study.   First, the results for nuclear power plants are entirely suspect because nuclear plants would not be built at all, absent a huge number of subsidies.  Several articles on SLB discuss the many and quite substantial subsidies that nuclear plants enjoy, summarized here as very limited liability from a meltdown and radiation-induced harm, construction loan guarantees, direct Federal payments for all power produced at 2.3 cents per kWh (for the first 10 years of operation), safety regulations relaxed to allow plants to continue operating, protection from almost all lawsuits during construction, laws changed to allow builders to charge existing customers for construction funds, state funding in the millions per year to "preserve jobs" and keep uneconomic nuclear plants operating, and Federal payments for spent fuel disposal and handling. 

It is also not quite clear on the coal plant LCOE, if these include or exclude pollution abatement equipment - not including Carbon Capture and Storage, or CCS.    If no pollution abatement costs are included, then the LCOE is too low because that is a form of federal subsidy.  

Finally, a note on the low-end costs of nuclear power: Lazard shows installed costs of $6,500 per kW (low end), and $11,800 at the high end (study, p. 11).   Certainly in the US, no nuclear plant could be built for under $10,000 per kW, so the low end figure is suspect.  Part of the trouble is the time for construction, 69 months (study, p. 20).   New nuclear plants in the US and Europe require at least double that, more than 10 years.  

Wind LCOE

The Lazard study has some questionable assumptions that produce the LCOE for Wind, at $30/MWh for the low end.   Per p. 19, that is based on on-shore, installed cost of $1200 per kW, and 55 percent annual capacity factor.   DoE annual reports thus far have nothing quite so optimistic, instead having $1600 per kW, and 38 percent capacity factor in the best areas.  It is not clear to me exactly how Lazard obtained the low-end data for Wind.   

Conclusion

The results for wind, onshore and with 2016 results, should be approximately $43 per MWh (since projects are operating today with that total sales price).   For US policy makers, it must be noted that the nuclear LCOE of $112 per MWh, low-end per Lazard v. 11.0, is essentially unattainable. 

Still, it is nice to see such a study.  The general impression that wind is cheaper, and nuclear more expensive, is correct.   Other studies have also arrived at the same conclusions. 


Roger E. Sowell, Esq.
Marina del Rey, California
copyright (c) 2017 by Roger Sowell - all rights reserved


Topics and general links:

Nuclear Power Plants.......here
Climate Change................here  and here
Fresh Water......................here
Engineering......................here  and here
Free Speech.................... here
Renewable Energy...........here  




Monday, August 28, 2017

Why Time-Of-Use Electricity Pricing Should Be Mandated

A Rationale for Time-of-Use Electricity Pricing 

UPDATE: 3-14-2019, CPUC issues TOU statement and how it will impact customers. see added material at end of this article -- end update

In light of California's Public Utility Commission's (CPUC) recent decision and order to allow San Diego Gas and Electric (SDGE) to charge retail customers a time-of-use premium and extend the TOU hours from 4 p.m. to 9 p.m., this article is well worth the long read to gain an understanding of what TOU is and why it is important.   see link to CPUC decision
Figure 1.   California Grid Demand (CAISO) on 8/28/2017
showing Total Demand (blue) and Net Demand (green)
where Net Demand is Total less Solar and less Wind
With the greatest demand year-to-date, almost 48,000 MW,
Solar and Wind combined for 6,300 MW at 17:30 hours
This avoided running expensive peaker power plants


An uproar ensued "on another blog" as they say, when I had my recent article on the CPUC decision republished there.   The commenters "on another blog" were, shall we say, less than civil.    One of the themes "on another blog" and the comments was that Sowell has no heart, no compassion for the poor who will be badly impacted by mandated time-of-use rates.    That could not be farther from the truth.   My life has been spent in many efforts to combat poverty, make various retail products more affordable, arguing and advocating strongly against commercial nuclear power because of the high electrical prices that result, and advocating for wind power due to the reduced natural gas prices that brings.   Although I never, ever, discuss my legal work, I can say that many of my cases (perhaps most) are on a pro-bono basis or at steeply discounted fees.  

It appears to me that many people doing the most howling are perhaps the most un-informed on the subject of time-of-use pricing.  

The article below is from 2003.   In the ensuing 14 years, much as changed, but the fundamentals are still true.  Technology has also greatly improved.   It is now a trivial thing to purchase an inexpensive yet robust appliance timer that can, for example, start a loaded dishwasher in the night after the expensive TOU power period ends.    The same is true for a clothes washer that is loaded in the evening, then runs so that the end of the cycle is early the next morning.  The homeowner or apartment renter can easily move the clean wet clothes into the clothes drying machine at that time.  One can also install a timer device on the refrigerator to prevent it from running between 4 pm and 9 pm, the peak TOU pricing window in San Diego.    One can also prepare healthy, nutritious meals in a slow-cooker with a timer, set to start after the 9 pm time frame.  

The howling complainers appear to object to the high cost of running an air conditioner during the peak 4-9 pm time frame.   That, too, can be minimized by first, applying for a poverty discount from the utility.  Second, many people already run a freezer to make ice during the night, during off-peak hours.   The ice can then be melted near a fan the next day to chill the home or apartment.   One can also purchase a water-freezing or chilling appliance to accomplish the same result: use electricity at night at cheap prices, then cool the home the next day and not use expensive TOU peak power.  

Finally, devices such as lights, TV, computer charging. and other small loads can be powered with a rechargeable battery system, if and when the prices for the battery and control systems become favorable.  

The article is shown below. (see link to article online) This was published in 2003 in the International Association for Energy Economics Conference Proceedings, Prague.   (end of Sowell commentary) 

I. INTRODUCTION.

A time-of-use (TOU) pricing program – entailing for all retail electricity consumers effective differential pricing for peak and off-peak use and meters capable of recording such use – is a public good.1, 2 For this reason, government should mandate implementation of TOU pricing programs by requiring participation by all retail consumers. In particular, such programs should be extended to cover residential and other small retail consumers who presently – in contrast to most industrial and commercial consumers – are generally not participants in TOU pricing programs.

When a state public utilities commission mandates implementation of an effective universal TOU pricing program, the consequent reduction in system-wide peak electricity demand will result in reduced production costs and thereby a reduced price structure for all consumers. As with any public good, this latter benefit cannot be subdivided and will accrue to all consumers – including those who fail to reduce or shift their peak-period demand. This situation parallels the well-known example of a national defense program as a public good. In this latter case, the federal government mandates implementation of the defense program by requiring that all taxpayers participate in the funding of the goods and services needed for national defense.

From a macroeconomic viewpoint, it has become well-accepted in the energy industry that peak-period demand by consumers must be reduced, first, in order to utilize system resources most efficiently in the short-run and, second, in order to contain the need to expand system infrastructure in the long-run. In the short-run, when electricity demand is at or near its peak level, supply is highly inelastic as less efficient generating units must be brought on-line to satisfy demand. Under these circumstances, even a small reduction in short-run system-wide demand can result in an appreciable reduction in system marginal costs. In the long-run, supply is more elastic; nonetheless, a reduction in system-wide peak demand will result in a reduced need for new generation and transmission facilities, thus avoiding, or at least postponing, additional capital outlays.

Industry experts have long struggled with these issues and have sought to identify effective means to reduce peak-period demand. Their search, however, has been for the most part unsuccessful as it has generally not included extension of TOU pricing mechanisms to residential and other small retail consumers – residential consumers alone account for the largest share of electricity consumption. Often instead there have been appeals for voluntary reductions – as were made in California during its recent energy shortage. But usually such appeals have been only marginally effective at best, even during short-term emergencies. In contrast, the expansion or introduction of TOU pricing programs that would ensure universal coverage by the inclusion of all retail consumers can achieve significant reductions in peak electricity demand and significant associated cost savings. These reductions result most often occur through a shift of electricity demand to off-peak periods, but may also result – although not necessarily – from an absolute reduction in consumption.

On the microeconomic level, in order to implement a TOU pricing program, electric meters used by retail consumers must be capable of recording both the volume of electricity demand and the time of such demand. Most electric meters currently installed in the United States, however, are not able to record time-of-use since utilities traditionally have charged small retail consumers a flat perunit rate on the total volume of electricity demanded, regardless of time of day or time of year. Thus, a move from such flat-rate pricing to TOU pricing will require the installation of real-time meters for most retail consumers. However, these consumers – particularly residential consumers – are not likely to voluntarily purchase the real-time meter needed to participate in a TOU pricing program since for them the cost of a real-time meter is likely to exceed the discounted stream of future savings from reduced charges. This occurs because participation is likely to be limited when it is voluntary, and the resultant reduction in system-wide marginal supply costs and the associated savings will be modest.

If, however, all retail consumers – particularly residential and other small retail consumers – were required to install real-time meters and to make electricity demand decisions on the basis of effective differential pricing under a TOU program, aggregate reduced peak-period demand could be expected to result in system-wide cost savings that would exceed the aggregate cost of real-time meter installation owing to a resultant sizeable movement down the supply cost curve. Moreover, with mandated participation, the unit cost of installed meters could be expected to decline due to economies of scale. The aggregate savings from lower electricity charges realized beyond the cost of installing real-time meters are the public benefit engendered by a TOU pricing program. But these savings can only be realized if all retail consumers participate in a TOU pricing program. Therefore, such a program is a public good and must be mandated.

II. THE NEED FOR TOU PRICING AND REAL-TIME METERING

A. Some Characteristics of the Electricity Market

The electricity market is somewhat unique in that electricity demand – as that term is conventionally understood – can be both elastic and inelastic depending on the time frame and the pricing structure. In order to understand this apparent anomaly, it is important to distinguish between electricity demand and electricity consumption. To this end, the term demand in this paper refers exclusively to the instantaneous electricity load or rate of use – in other words, the draw on system resources as measured by the instantaneous output required of generation resources. In contrast, the term consumption refers to electricity use over time.

The purpose of price-responsive demand systems generally, and TOU pricing in particular, is to reduce demand – as defined above – during peak times by shifting it to off-peak times even if total consumption (peak plus off-peak) remains unchanged. Thus with these definitions, it becomes clear that electricity consumption can be observed to be inelastic while electricity demand at a specific time can – if priced effectively – be observed to be elastic. It is this characteristic of the electricity market that allows TOU pricing to be effective even when increases in flat-rate prices have limited effectiveness in reducing demand. The problem with flat-rate price increases is that they are targeted at reducing total consumption of a highly inelastic commodity – a difficult goal to realize. In contrast, TOU pricing is able to take advantage of the relatively greater elasticity of time-specific demand.

The relative inelasticity of electricity consumption and its non-responsiveness to flat-rate price increases arise largely for two reasons. First, with reference to both the short-run and the long run, electricity has become fundamental to maintaining and improving the quality of life. The technological developments that have significantly improved the quality of life over the past century have been largely dependent on electric power. Consequently, consumers are reluctant to reduce electricity consumption since they are reluctant to undergo a deterioration in their quality of life. In witness to inelastic consumption and consumer attitudes, electric systems in industrialized countries have been constructed to provide virtually-guaranteed electricity when demanded by users. In the United States, for example, utilities strive for a 99.9 percent or better reliability factor – meaning that 99.9 percent of electricity demanded will be delivered.

Second, in the short-run, electricity consumption also is inelastic and non-responsive to price increases because electricity is essentially an input to durable goods that have long lifespans and are replaced only slowly in response to higher prices for the input. For example, consumers will not readily replace a serviceable electric hot water heater with a natural gas heater in response to a sharp electricity price increase relative to natural gas. 

But, they will make this substitution in the long run when the durable good needs replacement if the price differential between electricity and natural gas has remained sufficiently large and persistent. In the interim, electricity consumption is inelastic.

B. The Pricing of Electricity and the Need for Price-Responsive Demand

Electricity use by residential consumers in the United States traditionally has been measured and billed on an aggregate basis over the course of an entire billing cycle – usually one month. Under this system, customers pay for electricity based on their entire consumption (measured in kilowatt-hours) over the billing period regardless of when the electricity is demanded. On the other hand, large-scale industrial and commercial users in recent years have been increasingly billed on a TOU basis.3

This difference in pricing regimes is rooted in the historically high cost of introducing TOU meters for residential and other small retail consumers. The hardware cost of such meters has fallen in recent years, however, and recent data place the cost at approximately $80 for a retrofit and up to $200 for a replacement meter.4 These costs exclude installation charges and the cost of additional infrastructure needed at the utility. Despite the now lower prices of TOU meters, for most residential consumers – and even some small commercial consumers – the cost of purchasing and installing a TOU meter is still likely to exceed the present value of the savings offered by reduced electricity charges. This situation occurs because few customers are likely to apply a rate of time discount to the future cost-saving stream that is sufficiently low to justify the outlay cost for a TOU meter.

Moreover, the ability of utilities to provide financial incentives to retail consumers to purchase TOU meters and to enter TOU programs is limited largely for two reasons. First, the potential electricity cost savings that a utility can offer to a retail customer for participation in a TOU program is limited by the cost savings that would accrue to the utility itself. But these savings are likely to be modest because, while most electric utilities in the United States are for-profit entities, their profits are constrained by state regulation. 

Commonly, state public utility commissions permit utilities to recover all of their prudently-incurred costs plus a set rate of return on their capital. However, retail electricity rates charged by a utility generally change only following a rate review by the commission – which occurs usually every several years or so. At that time, the state commission is likely to recognize any savings to the utility resulting from implementation of a TOU pricing program and, all things being equal, to require the utility to lower its rates to reflect its reduced costs. Thus, the savings to the utility resulting from implementation of a TOU pricing program – or a sizeable portion thereof – are likely to accrue to the utility only until its next ratemaking proceeding (rate case).5 Second, as the reduced peak electricity demand of a single small retail consumer is unlikely to have an appreciable impact on the utility's costs, the utility is necessarily limited in its ability to promise this consumer significantly reduced rates for entering a TOU pricing program. For both of these reasons, there is little if any incentive for an electricity utility to voluntarily implement a TOU pricing program or even to offer a program to small retail consumers – such as residential consumers – for their own choosing.

Residential customers as a group, however, account for the largest share of electricity consumption in the United States. The U.S. Department of Energy estimates that for calendar year 2001, residential customers used 35.4 percent of the retail electricity consumed in the United States, as compared to 29.3 percent for industrial users and 31.9 percent for commercial users.6 Due to the lack of information on time of use by non-TOU consumers, it is difficult to determine how much residential consumers contribute to peak demand. However, it appears likely that residential demand plays a large role in determining the level of system-wide demand during all hours. As a result, while the economic incentives may not exist for either utilities or individual residential or other small retail consumers to adopt TOU pricing, the potential to reduce system-wide demand during peak periods by implementing TOU pricing for these consumers is large indeed.

Participation in TOU programs by residential consumers is presently limited in the United States. Apart from the reasons laid out above, some industry observers have suggested that residential consumers, regardless of TOU meter costs, simply prefer the simplicity of fixed-rate rather than TOU-pricing. However, at least one industry observer has criticized this latter position, suggesting that limited participation is simply the result of consumer inertia and that, if TOU pricing were offered as the default, few consumers would opt out.7 Yet TOU programs do exist and are available for customers, if only on a limited basis and/or as part of a pilot program. While information from a broad survey on the scope of residential TOU pricing is not available, anecdotal evidence suggests that many utilities do offer TOU pricing to residential customers. For example, the Potomac Electric Power Company (PEPCO), which serves Washington, DC, and its northern suburbs, has offered TOU pricing to its Maryland residential customers since 1984.

Despite the debate over why TOU programs have not been implemented in the United States on a more widespread basis, there is little disagreement among industry experts that price-responsive demand (PRD) – a more general concept which includes TOU pricing among other concepts – is needed.8 Due to the sizable contribution of residential consumers to retail demand, residential load is a potentially significant source of price-responsive demand. Although industry observers have discussed this issue for some time, it has been only recently that policymakers – at least at the federal level – have pointedly noted the need for more price-responsive demand. For example, the Federal Energy Regulatory Commission, charged with overseeing the wholesale – but not retail – power markets in the United States, recently commented in proposed rulemaking concerning the development of standard wholesale energy markets that the lack of price-responsive demand is a "significant structural problem" in wholesale energy markets.9 Similarly, recognizing the importance of TOU pricing, the drafters of the energy bill recently considered by the United States Congress included a provision that would have required utilities to offer TOU pricing to their consumers.10 Finally, Alfred Kahn, the well-known economist and energy expert, has commented that the absence of price-responsive demand is the single greatest structural flaw of energy markets.11

The recent attention by federal policymakers to price-responsive demand may be the result, at least in part, of California's 2000-2001 energy shortage. It is not unreasonable to consider that low flat-rate retail electricity prices, resultant high demand, and inelastic consumption taken together were leading causes of the state's troubles. During the shortage, demand for electricity in the region controlled by the state's grid operator – the California Independent System Operator Corporation – peaked at 43,784 MW in August 2000.12 This level of peak demand represented a 6.7 percent increase over the average peak demand of the ten years prior. Perhaps cognizant that most consumers would feel little immediate financial impact from the high wholesale prices brought on by the shortage, California state officials and the transmission grid operator issued pleas for voluntary reductions in demand. These efforts were only marginally effective, and consequently the grid operator was required to implement planned involuntary service curtailments – rolling blackouts – to prevent widespread collapse of the grid.13 In this connection, it is worth noting that the results for one recent pilot TOU program indicate that TOU pricing for residential consumers was able to reduce peak-period demand by five percent – a percentage reduction not much smaller than the percentage increase in California's peak period demand at the time of its energy problem.14

III. TOU PRICING AS A PUBLIC GOOD

In microeconomics, a public good is a good or service that lacks depletability and excludability.15 Non-depletability means that one person's use or enjoyment of a public good does not reduce the ability of others to enjoy it and receive its benefit. Non-excludability means that persons cannot be prevented from enjoying the benefits of a public good regardless of whether they pay for it or not. Given this non-depletability and non-excludability, the problem posed by a public good for economics and public policy is that few if any people would be willing to pay for a public good voluntarily. Rather, if a public good is to be produced, the government must mandate the financial support of the good by all persons who will enjoy its benefits. A universal TOU pricing program for all retail electricity customers with effective differential pricing for peak and non-peak electricity use satisfies the two basic criteria for a public good. Accordingly, such a program should be mandated.
Although economists have only recently begun to model the electricity supply market, it is generally recognized that, when not subject to price regulation, the short-run supply curve for electricity is relatively elastic at low volumes of production, but becomes highly inelastic as the quantity of electricity produced nears the maximum level that the system is capable of generating.16 Under these circumstances of inelastic supply, even a small reduction in short-run demand can result in an appreciable reduction in system marginal costs.

But how can an electric system achieve such a reduction in short-run demand? The fact of the matter is that consumers will not reduce electricity demand unless and until they have a financial incentive to do so. On a long-run basis, retail consumers can be incentivized to reduce demand through higher prices for electricity generally. However, such an approach would likely overachieve insofar as it would likely reduce overall consumption when the primary goal is to reduce peak demand. Reductions in short-run peak-period demand may be achieved by providing consumers sufficient financial incentives to either reduce demand during peak periods or, more likely, to shift demand from peak to off-peak periods – where the short-run market equilibrium is on a less inelastic/more elastic portion of the short-run supply curve and thus marginal production costs are lower.

A TOU pricing program will effectively provide the needed financial incentives for consumers to shift their demand from peak to off-peak periods – provided there is a sufficiently large price differential depending on the time of day and time of year of electricity use.17 For example, the residential consumers participating in PEPCO's TOU program pay in non-summer months (November through May) a generation service charge of 1.9¢/kwh off-peak and 2.7¢/kwh – or 42 percent more – on peak (and 2.1¢/kwh during the shoulder periods). In summer months, they pay 1.7¢/kwh off peak and 19.4¢/kwh on peak – an eleven-fold higher rate (and 2.2¢/kwh in shoulder periods). By comparison, residential consumers not in PEPCO's TOU program pay a flat-rate generation service charge of 5.5¢/kwh during the summer months and, during non-summer months, pay 3.5¢/kwh for the first 800 kilowatt-hours and 2.7¢/kwh thereafter. This TOU pricing regime provides consumers with strong incentives to shift their discretionary electricity demand to off-peak periods by, for example, shifting the use of washing machines, dryers, and hot water heaters. Moreover, high summer TOU peak-period rates like those charged by PEPCO encourage some time period shifting of electricity demand for air conditioner use by cooling down before and after the peak period and using higher air conditioning temperature settings during the peak period.
Colledge, et al., estimate that it would cost approximately $25-30 billion to equip all mass market electricity customers in the United States with the infrastructure needed for TOU pricing, and that operations and maintenance would cost approximately $7-8 billion per year.18 If peak demand were to fall nationwide by five percent, they estimate that some $15 billion in electricity costs could be saved – resulting in the investment in TOU pricing infrastructure being recovered in five years. They also note that such a reduction in peak period demand would permit utilities to avoid or delay the installation of up to 250 peaking facilities. Another study estimates that the annual savings from implementing TOU pricing nationwide could amount to $10 billion to $15 billion.19

Further research is required to determine the circumstances under which a mandated TOU pricing program for all consumers would be cost-effective. To a large extent, the cost-effectiveness of such a program would depend centrally on two factors: first, the frequency with which short-run demand in a particular electricity system reaches the highly inelastic portion of the supply curve; and, second, the quantity of discretionary demand that consumers would, if provided the appropriate financial incentives, shift to off-peak periods. For example, in California, a widespread TOU pricing program may hold significant benefits since serving peak demand in the state often requires the use of 90 percent or more of available generating resources. On the other hand, in a system with significant generating reserves at all times, demand may never reach the inelastic portion of the supply curve and thus a shift of demand from peak to off-peak hours in such circumstances may not appreciably reduce system-wide short-run marginal costs. These issues as well as those concerning political feasibility of implementing a TOU pricing system would need to be explored before participation in a TOU pricing program is required of all consumers.

This article first appeared in the Prague 2003 IAEE Conference Proceedings, June 4-7
________________________________________



† The views expressed in this paper are solely those of the author and do not necessarily represent the views of Troutman Sanders LLP or its clients. The author would like to thank Troutman Sanders LLP for its generous support of this paper.

Footnotes:

1 Retail electricity customers in the United States are generally classified into one of three categories –industrial, commercial, and residential.

2 Peak hours are those during which system-wide electricity use is greatest. Commonly, the peak period begins between 8 am and noon and ends between 6 pm and 8 pm, Monday through Friday, with off-peak periods occurring during the remaining weekday hours and throughout the weekend days. The precise times for these periods vary from one region of the United States to another and even from one utility to another within a region.

3 Georgia Power, for example, introduced TOU meters for large industrial customers in 1992. Ten years later, approximately 1,650 business customers used such meters, with peak demand for these consumers falling 17 percent since they began using TOU meters. Justin Colledge, et al., "Demand Side Management: Power by the Minute," Power Economics, Feb. 28, 2002.

4 These meters generally require either traditional meter-reading techniques or a roaming receiver truck to retrieve data. A new generation of electricity meters has been developed in recent years that uses a wireless transmitter or power-line-carrier technology to send data directly to the utility, either over cellular telecommunications infrastructure or over the power lines themselves. Such meters are estimated to cost $160 to $320 exclusive of the cost of installation and the cost of infrastructure at the utility's end. Id. at 25. A November 1998 study by Arthur Andersen indicated that the per meter costs of ad hoc TOU meter installation are five to six times the per meter costs for a broad, utility-wide installation of such meters. Arthur Andersen, "Cost Impact of Competitive and Network Metering in New York State – Final Report," Nov. 1998, cited by "Advanced Metering: Policymakers Have the Ball," Public Utilities Fortnightly, Sep. 15, 2002, at 26

5 In the United States, this system of performance-based ratemaking (PBR) generally provides electric utilities little incentive to expend resources in order to reduce operations and maintenance costs except to the extent that such expenditures can be recouped before the utility's next rate review. Recognizing this lack of incentive for innovation, some utility commissions have begun to adopt a modified PBR system under which, for example, half of the cost savings are passed on to consumers through reduced rates and half accrues to the utility through increased retained profits.

6 U.S. Department of Energy, Energy Information Administration, Electric Power Monthly, September 2002, Table 44. The year 2001 is the last year for which, as of this writing, a complete calendar year of data was publicly available. The balance of electricity consumption (3.4 percent) is attributable to uses other than by industrial, commercial, and residential consumers, such as public street and highway lighting, other sales to public authorities, sales to railroads and railways, and sales for irrigation.

7 See Lisa Wood, the Brattle Group, Comments Delivered at Seventh Annual Washington Energy Policy Conference, "New Developments in Electric Market Restructuring," Paul H. Nitze School of Advanced International Studies, The Johns Hopkins University, May 21, 2002. In this regard, the May 2001 effort by Puget Sound Energy to make TOU pricing the default pricing system for 300,000 of its residential and small business customers resulted in only one percent of customers opting out of that system.

8 PRD generally refers to any system under which demand is significantly responsive to price changes. In other words, PRD refers generally to systems designed to enhance the elasticity of demand. In the context of electricity, PRD systems include, in addition to TOU pricing and other similar regimes, interruptible load programs and demand bidding. In the former, customers agree in advance to have their energy use curtailed when system demand or real-time wholesale prices reach a certain level. In the latter, buyers offer into realtime energy markets a quantity of demand that they agree to curtail for a certain price.

9 U.S. Federal Energy Regulatory Commission, Remedying Undue Discrimination through Open Access Transmission Service and Standard Electricity Market Design, Notice of Proposed Rulemaking, FERC Stats. & Regs. 32,563 at P 113, 390-94 (2002).

10 United States Congress, H.R. 4 (Pub. Print) § 241, Energy Policy Act of 2002, 107th Congress (2002).

11 Jamie Wimberly, President of the Center for the Advancement of Energy Markets, Comments Delivered at Seventh Annual Washington Energy Policy Conference, "New Developments in Electric Market Restructuring," Paul H. Nitze School of Advanced International Studies, The Johns Hopkins University, May 21, 2002.
12 California Energy Commission, 1988-2000 Historical Coincident Peak Demand and Operating Reserve, available at www.energy.ca.gov/electricity/peak_demand_and_reserve.xls. This figure represents peak demand in the CAISO control area on the day of the year with highest statewide peak demand, i.e., state coincident peak demand. The CAISO's control area encompasses approximately 85 percent of the state's demand.

13 The U.S. Department of Energy's Energy Information Administration (USEIA) estimates that during the summer of 2001 involuntary peak demand reduction during electricity outages ranged from 1,825 to 5,500 MW. The USEIA states that "one of the significant uncertainties in these projections of electricity outages is the amount of electricity demand reduction that is either voluntary or motivated by high electricity prices." USEIA, "Electricity Shortage in California: Issues for Petroleum and Natural Gas Supply," June 2001, available atwww.eia.doe.gov/emeu/steo/pub/special/california/june01article/casummary.html.

14 See Colledge, et al., supra n. 3, noting a 2001 pilot program by Puget Sound Energy (PSE). This program involved 300,000 residential and small business customers. See also"All About Time-of-Use Metering," Metering, 2000 Issue 3. Noting TOU experiments in California, Washington and Florida, this article indicates that peak demand could be reduced by three to five percent.

In late 2002, PSE terminated the program due to the fact that on average customer bills increased 80 cents per month. See Ahman Faruqui & Stephen S. George, "Demise of PSE's TOU Program Imparts Lessons," Electric Light & Power, Jan. 2003, at 1; Candace Heckman, "PSE Plan Expected to End," Seattle Power-Intelligencer, Nov. 15, 2002, at B4. For the author, this situation is evidence, not that widespread TOU pricing cannot reduce costs, but that costs cannot be reduced unless TOU pricing is widespread.

15 Most economics texts agree that non-depletability and non-excludability are the key factors in defining a public good, although the texts disagree to a certain extent as to whether each of these two factors is a necessary condition or simply a common condition. See, e.g., James M. Henderson and Richard E. Quandt, Microeconomic Theory at 298 (3rd ed. 1980) ("Each member of society gains satisfaction from the total output of a public good. No one's satisfaction is diminished by the satisfaction gained by others, and it is not possible for anyone to appropriate a public good for his own personal use, as is the case with ordinary goods."); William J. Baumol and Alan S. Blinder, Economics Principles and Policies at 939 (4th ed. 1988) ("A public good is defined as a good that lacks depletability. Very often, it also lacks excludability."); Walter Nicholson, Microeconomic Theory at 815-15 (6th ed. 1995) ("A good is a (pure) public good if, once produced, no one can be excluded from benefiting from its availability. Public goods usually also will be non-rival, [i.e., consumption of additional units involves zero social marginal costs of production] but that need not always be the case.").

A TOU pricing program is characterized by non-excludability as the benefits of reduced system-wide costs engendered by such a program will accrue to all users of the electric grid regardless of whether or not they participate in such a program. Similarly, a TOU pricing program is characterized by non-depletability as one consumer's participation does not prevent others from similarly participating.

16 The issue of why the supply curve becomes so inelastic as it approaches the maximum system output level has been the subject of much debate since the California energy crisis of 2000-2001. While some assert that this situation is the result of low-efficiency peaking generators seeking to recover their fixed costs during only a few hours of the year, others assert that sellers engage in price gouging when demand is at its highest.

17 Under the PSE pilot program noted above, TOU rates were approximately 15 percent lower than flat rates during off-peak hours and 15 percent higher than flat rates during peak hours. See Faruqui & George, supra, n.14. The author believes that the relatively small rate spread may have been a cause of the program's failing to deliver the expected savings to participants.

18 See, supra n. 3.

19 McKinsey and Co., "The Benefits of Demand-Side Management and Dynamic Pricing," May 2001.

Original Copyright 2017 Thomson Reuters. All rights reserved.  
Re-Published on SowellsLawBlog as educational material, not for profit. 

UPDATE 3-14-2019  "In a big shift that’s being watched around the nation, millions of California residents will soon start experiencing a new way of paying for the electricity they use. For most residential customers, this should result in lower bills and the satisfaction of knowing they’re doing right by the planet. But none of this will happen without some changes in personal behavior. If you haven’t yet heard the acronym TOU, which stands for Time of Use energy pricing, odds are good you will in the weeks and months ahead. Public outreach and educational campaigns are already. Taking root across the state. But it
might be more appropriate to use the term Time of Savings, because that’s what most electricity customers are likely to find appealing. And that doesn’t refer only to money. By planning their heaviest electricity use outside the peak periods when demands for power is highest—generally from 4 p.m. to 9 p.m.—California electricity users can help the state become less reliant on power generated from fossil fuels, which emit the greenhouse gases that cause and exacerbate climate change. And if customers can switch some of those electricity intensive uses to hours of the day or night when the state’s electric grid has
a greater supply of solar and wind energy, most people will see a reduction in their monthly bills.
“Transitioning millions of people to time of use pricing is a big deal for California,” said Michael Picker, President of the California Public Utilities Commission (CPUC). “It can motivate people to use cleaner, renewable energy, so it’s an effective tool in the fight
against climate change, and it can help in managing the electric grid without having to build new gas-fired plants to meet peak demand. And for most people, it can lead to
savings on their monthly bills without having to change their behavior very much. It gives customers more control over their own energy use and California’s.” The transition to the new way of charging for electricity stems from residential rate reform legislation passed in 2013, and a follow-up CPUC decision that ordered pilot TOU programs for the state’s three large investor-owned utilities: Pacific Gas and Electric Company (PG&E), San Diego Gas & Electric (SDG&E), and Southern California Edison (SCE). The CPUC also ordered marketing and educational outreach to consumers, with pilot plans leading to mandatory TOU pricing starting this year. If customers don’t want to participate in the new TOU
rates, they can opt out. San Diego will be the first market where the utility is required to provide the time-based billing system that charges customers based not just on how much electricity they use, but also on when they use it. Eventually, some 750,000 customers in the SDG&E service area will be affected, California is a world leader in solar and wind energy and the state is well on its way toward meeting legislative requirements that it get 50

Sowell commentary:   

How will this work in practice?  One way is to make every day the same as if a Flex Alert is in effect.  A Flex Alert is issued in CA when there is a high electricity demand forecast, and customers are requested to run major appliances after 9 pm, and set their A/C thermostats up to 78 degrees F.    I suspect that savvy customers will learn quickly to cook meals in a slow cooker (or crockpot) overnight, to avoid using the stove or oven for cooking dinner.  Also, I suspect there will be quite a number of systems installed to chill water for overnight storage when electricity price is low, then use that chilled water to cool the house the next day.  This may also bring back the heat-driven air conditioner industry, where one burns natural gas in an absorption chiller to produce chilled water for cooling a home.   The economics may finally swing to favor absorption chillers.   Next, it won't take much for customers to use a timer to run a clothes washer from 9 am to 3 pm, when electricity has not yet reached the peak pricing, then run the clothes dryer after 9 pm.  Finally, such pricing will almost certainly improve the economics for installing a home battery storage system that could be charged with roof-mounted solar panels.  -- end update 3-14-2019



Roger E. Sowell, Esq.
Houston, Texas
Original material copyright (c) 2017-2019 by Roger Sowell - all rights reserved



Topics and general links:

Nuclear Power Plants.......here
Climate Change................here  and here
Fresh Water......................here
Engineering......................here  and here
Free Speech.................... here
Renewable Energy...........here  




Saturday, October 1, 2016

Renewable Energy Saves California from Grid Blackouts

Subtitle: Record-Setting Solar Power Reduces Natural Gas Demand

The peak summer heat is now ended in Southern California, indeed, a winter storm warning was issued for the central Sierra Nevada mountains.  One short and fairly mild heat wave occurred last weekend, with temperatures measured at Los Angeles (USC Campus)  reaching 104 degrees F for one day.  (see adjacent Figure 1).   The orange oval shows the period in which heat waves typically occur, this year only twice did temperatures break 100 degrees F.   The major conclusion is that zero blackouts occurred, because renewable power from solar PV, solar thermal, and wind turbines produced electricity at rates up to 10,000 MW throughout the summer. 


Figure 1  -  2016 year-to-date temperatures
at Los Angeles, California
As is well-known, officials have concern that grid instabilities or blackouts would occur this summer during heat waves, because the natural gas storage supply is much reduced due to the Aliso Canyon storage facility being out of operation.  

However, solar power and wind power need no natural gas, and provided power routinely through the summer.   Solar PV actually broke records for power production.    

The California grid has many efficient, combined-cycle gas turbine power plants with quick response capability to adjust their output when solar or wind output changes suddenly.    The state also imports some power from adjacent states, notably nuclear power from Arizona, hydroelectric from Nevada (Hoover Dam), and both wind and hydroelectric from Washington.    It is notable that long-distance transmission lines are required to ship the power into California.  It is also noteworthy that the adjacent states have surplus power to sell to California and do so profitably. 

Now that Fall and Winter are here or looming, the gas shortage continues due to Aliso Canyon's problems.   However, wind power increases in those seasons, which offsets the declining solar power production.    Next year will have even more solar power production as California installs even more PV power plants.   The state's renewable energy plan requires approximately 3,000 MW of renewables installed each year.  Almost all of that will be solar PV, since wind locations are essentially built out, and solar thermal has much worse economics. 

Roger E. Sowell, Esq.
Marina del Rey, California

copyright (c) 2016 by Roger Sowell, all rights reserved.





Monday, June 27, 2016

Designing an Electrical Grid From Scratch

Subtitle: Ranting and Raving Does Not Produce A Useful Result

Sometimes one just has to laugh at the things others complain about, and even rant and rave about.  A blog article I wrote recently produced a rant (on WUWT), about how the California electrical grid and its operation are grossly unfair and should never have been allowed to reach the condition that it is in today.   The chief complaint, it appears, is the price paid by residential customers, what is known as the rate structure.   California does have some high rates, it is true, by law there are a few tiers or levels of price depending on the season and how much power one uses.   The more use in the summer during peak
California Energy Commission - major electric transmission lines 
demand, the higher the price.   Conversely, low use in Spring during offpeak hours has a low price. 


Another loud complaint is the use of renewable generating resources on the California grid. Most of the howls of indignation appear to be directed at solar power and wind power systems.   It seems that geothermal is not on the list that causes anger.    The utter confusion, indeed ignorance, of how hydroelectric power is treated as a renewable source or not is perhaps understandable.  Basically, most systems of 30 or smaller MW count as a renewable, while most larger systems do not.  

I requested the unhappy commenters to provide their solutions to how California should proceed, what would and would not be included in their ideal grid.   Their goal, of course, is to have cheaper power.    No response as of this date, however.   It seems it is much easier to complain than it is to offer workable, sound solutions.    I should point out that I have never seen a utility reduce their rates when adding new generation assets, or for transmission or distribution assets.   In fact, where nuclear power plants are being built, the utility (in Georgia, USA) obtained a special law from the state legislature to increase customers' power bills for the several years of the nuclear plant's construction. 

Therefore, I put together a few items that one should, and in some cases must consider (laws of many types play into the electricity issue).  

California already has quite a mix of generating types, including nuclear, gas-fired, petroleum coke-fired, oil-fired, diesel engines with generators, geothermal, hydroelectric, wind, solar PV, solar thermal, biogas, and biomass.   Some storage is already provided by batteries, pumped storage hydroelectric, and a gravity rail system is under construction.  There are mandated combined heat-and-power (CHP) systems that replaced standard boilers.   In the gas-fired category, there are at least three types: steam, combined cycle gas turbine (CCGT), and peaker plants or simple cycle gas turbines.   However, at least a few peaker plants are also CCGT.  

Below is a list of generating technologies, with perhaps others existing that do not readily come to mind after a bit of research.    In no particular order, then, here is a list of 46 generating and 7 storage possibilities.   Note:  BL denotes Base Load design, LF denotes Load Following.   There are substantial initial cost and operating cost implications for Load Following vs Base Load designs.   Acronyms may be familiar to readers, if not I can provide a link to a resource. 

1 Nuclear BL PWR - AP-1000
2 Nuclear BL PWR - EPR
3 Nuclear BL BWR - ABWR
4 Nuclear BL SMR
5 Nuclear BL LFTR  - MSR Thorium
6 Nuclear BL HTGR
7 Nuclear BL Fusion - Tokamak
8 Nuclear BL Fusion - LIFE
9 Nuclear - LF PWR - AP-1000
10 Nuclear - LF PWR - EPR
11 Nuclear - LF BWR - ABWR
12 Nuclear - LF SMR
13 Nuclear - LF LFTR  - MSR Thorium
14 Nuclear - LF HTGR
15 Nuclear - LF Fusion - Tokamak
16 Nuclear - LF Fusion - LIFE
17 Coal Rankine - Med Pres
18 Coal Rankine - USC
19 Coal Gasified - IGCC
20 Hydroelectric Large
21 Hydroelectric Small
22 Natural Gas Rankine
23 Natural Gas CCGT
24 Natural Gas SCGT
25 Natural Gas Methane SMR - Fuel Cell
26 Geothermal Rankine
27 Wind Onshore HAWT
28 Wind Onshore VAWT
29 Wind Offshore HAWT
30 Wind Offshore VAWT
31 Solar PV - utility scale
32 Solar PV - residential demand reduction
33 Solar Thermal w/o storage
34 Solar Thermal w/storage
35 Solar Pond - Rankine
36 Biomass Burn - Rankine
37 Biomass Synthetic Methane (Park process)
38 Biogas Methane collection
39 Wave Various
40 Tide         Turbine
41 Ocean Current Turbine
42 OTEC Thermal - Rankine
43 River Current - turbine
44 Oil         Rankine
45 Diesel Engine
46 Natural Gas ICE engine - cogen and tri-gen
47 Storage Pumped Hydroelectric - onshore
48 Storage Pumped Hydroelectric - offshore - MIT spheres
49 Storage Pumped Hydroelectric - combined onshore and offshore
50 Storage Battery
51 Storage Capacitor
52 Storage Gravity - rail

53 Storage Compressed air

With those as the available cards in the proverbial deck, one must then have solid answers to a few dozen questions (or issues) about electrical grid design and operation.   Below are listed just a few of the hundreds of issues that must be resolved in an electrical grid.   I pose these to the ranters and ravers, with the full expectation that they will not ever provide any answers.   Perhaps merely reading the questions will give them pause, and a bit of respect for a grid as large and complex as the California grid.   

1. Power grid first of all must be safe
2. Power grid second, must be reliable
3. Power grid third, must sell affordable power
4. Utilities must obtain a reasonable return on investment
5. Power grid must meet all load conditions, all the time 
6. Account for variations in demand daily, weekends, seasonal
7. Account for planned and unplanned asset outages
8. Account for adverse weather, earthquakes, fire, flood, wind, tsunami
9. Account for blackouts and brownouts
10. Account for fuel supply issues including disruptions (coal, natural gas, etc)
11. Account for available space (if any) on railroads for coal imports from other states
12. Account for growth in demand, if any
13. Account for environmental impacts - wildlife, air, water, soil, radiation, noise, explosion, etc
14. Account for transmission and distribution systems
15. Account for customers' ability to pay - poor, elderly, etc
16. Account for power attributes as attracting or deterring commerce and industry
17. Pricing must also pay utilities for fuel and other operating costs
18. Account for critical services - hospitals, life-support systems at residences, etc
19. Account for cooling water, river, lake, ocean, or air-cooling, mixed-cooling
20. Account for customers' installation of solar on property, and wind; will you buy power from individuals?
21. Account for other states with offers to sell power to California, yes, no, what conditions
22. Account for large industry or commercial sites that self-generate, will you be their backup?
23. Account for large industry or commercial sites that produce excess - will you buy?
24. Account for location, siting, of generating assets, and environmental justice issues
25. Account for location and siting of transmission assets, distribution assets
26. Will you cooperate in a regional grid, or a very large regional grid?
27. For experimental technologies that need research and development - will you fund this?  How?
28. How will you determine acceptable pollution emissions to air, water, soil, and via radiation?
29. What levels of animal, bird, and fish deaths will you accept and how to justify these?
30. What level of grid reliability will you deem acceptable, and how to justify this? 99% or higher?
31. How will you ensure that grid reliability is uniform across all areas, so no group is discriminated against?
32. How will you price the power sales, by residential, commercial, industrial, transportation, or other method?
33. Will you have a flat rate, or a tiered pricing system, and why?
34. Will you encourage efficiency in use, or profligacy, or be neutral, and why?
35. How will you address energy profligacy by a rich few, and the increased generation assets that requires?
36. If nuclear is part of your assets, who pays for a nuclear disaster and related deaths? Property damage?
37. How will you bring electricity to a very small user in remote areas?  Not at all?  
38. Will you have above-ground or in-ground distribution, where and why?
39. Will you allow distributed generation, if so, at what size and where? 
40. How will you address the disparity in use vs location in California, with coastal areas
having mild summers and winters thus low usage, but inland areas
. having hot summers and cold winters thus much higher usage? 
41. For gas-fired peaker plants, if you have those, how will you regulate their use?
42. For large hydroelectric plants, if you have those, how will you decide where to put them?
43. How will you decide when to retire an asset, either generation, transmission, or distribution systems? 
44. On a daily and hourly basis, how will you choose which generating assets to run, which to order to stand by, and which to hold in reserve? 

45. How will you ensure complete compliance with all Federal Laws and regulatory agencies, including but not limited to FERC, Nuclear Regulatory Agency, PURPA, Clean Air Act, Clean Water Act, various national energy policy acts, and state agency regulations such as California Energy Commission, California Coastal Commission, California Public Utility Commission, California Independent System Operator, California State Water Resources Control Board, and California Air Resources Board? 

Have I any experience in any of these issues?  Absolutely, but just a bit.  My engineering experience includes economic justification and preliminary design of a CCGT plant that was installed and is still running near Houston, Texas at a large chemical plant.   I also performed a make-or-buy analysis many times, one notable example was for nuclear power to a large refinery using a small reactor.  Also, I did an economic justification with technology selection, and sizing for a large hydroelectric project overseas.  I had the nuclear power course in undergraduate school for nuclear chemistry, physics, reactor design, and remainder-of-plant design for multiple types of reactors.   I had a full guided tour of a large nuclear reactor in Perry, Ohio with a group of fellow engineers.  I was assigned to analyze completely the fiasco of the South Texas Nuclear Plant design and construction process, then report on the entire matter to my employer.  I have evaluated and made recommendations to several clients on their make-or-buy decisions for both electricity and steam in their large refineries and process plants.   As an attorney, I don't discuss my clients or my cases.  It is sufficient to say that I am quite familiar with many of the legal requirements for grid-scale electrical systems.  

With California presently in a crisis summer, with high loads on the grid and inadequate natural gas supplies due to the Aliso Canyon storage facility problems, it is not surprising that the grid is a popular subject.   Everyone seems to know what California should do.  It is easy to rant.   I wonder how many, if any, could provide answers to any of the issues above.  

Roger E. Sowell, Esq.
Marina del Rey, California